SN Technologies SA

Ignition Pellet D-700 - Technical data

 

Type classification

Ignition Pellet for ignition of inflammable Gases for a flare on e.g. a flame Tower.

 

General

The D700 is a Ignition Pellet launched through a conducting pipe by low pressure compressed air.               The mechanical fuse integrated in the Pellet body is specially adapted for the ignition of a charge with sparks effect.

 

Main characteristics

Mechanically ignited directly when emerging from the conducting pipe. Hermetically sealed.

 

Safety features                         

Main technical data

Safety for storage, transport and handling

Launching pressure - lower limit 4[bar]

No stored energy prior launching

Launching pressure - upper limit 20[bar]

The state of the fuse is permanently displayed

Arming time min. during launching at 4[bar] : 20[ms]

Drop resistance minimum 3[m] (safety test)

Ignition time when emerging of the conducting pipe 4[ms]

Safety clip

Length of conducting pipe lower limit 20[m]

Compatible mainly with MIL-STD 1316E

Length of conducting pipe upper limit 1000[m]

 

Diameter of conducting pipe 21 0.50[mm]

Reliability

Temperature limits storage -20 / +70[C]

Function and tightness controlled at 100%

Temperature limits function -10 / +80[C]

Reliability 99%

 

 

Dimensions

Weight

Diameter : 20[m]

Complete Pellet : 80[g]

Height : 95.5[m]

 
Not contractual - subject to change without notice - copyright sntechnologies sa 2003